2012 CSI TWIN VERTICAL GAS COALESCER (CSG) & PRESSURE REGULATION SKID
Autres
EUR € 95.023,12
EUR € 95.023,12 + GST = EUR € 104.525,43 (TVA applies to buyers in Australie)
Localisation d'item:BrisbaneBrisbane, Queensland, Australie 4000
Information sur le vendeur
Voir les informations du vendeurGénéral
Catégories
Autres
fabricant
CSI TWIN VERTICAL GAS COALESCER
Hours
0
Modèle
(CSG) & PRESSURE REGULATION SKID
Numéro de série
R5311-6
Etat
Occasion
Numéro de Stock
sale-ehub4329
Description
2012 CSI Twin Vertical Gas Coalescer (CSG) & Pressure Regulation Skid ($160,000 ex GST) (sale-ehub4329)
Make: Compressor Systems Australia Pty Ltd (CSI)
Year: 2012
Vessel Type: Vertical Gas Coalescer Vessel
Designed Service: Coal Seam Gas (CSG)
Design Code: AS 1210:2010
Hazard Level: B (AS 4343)
Registered Design Number: Q26409
- Does NOT INCLUDE Control System Module or Wiring
Mechanical (Each Vessel);
Internal Volume: 460 L
Orientation: Vertical
Shell Material: AS1548 PT460NR
Head Material: AS1548 PT460
Corrosion Allowance: 3 mm
PWHT: Nil
Weight;
Empty: ~550 kg
Full: ~850 kg
Pressure & Temperature;
Design Pressure: –101.3 kPa to 1,000 kPa
Maximum Operating Pressure: 930 kPa
Hydrostatic Test Pressure: 1,500 kPa
Design Temperature: –10 °C to + 85 °C
MDMT: –31 °C
Maximum Operating Temperature: 50 °C
Internals;
- Replaceable coalescing filter elements (micron rating TBC)
- Bottom liquid sump with drain connection
- Top removable head for element access
Total Installed Coalescing Volume: ~920 L
Pressure Regulation;
Make: Fisher (Emerson)
Model: Big Joe® Type 630
Function: Downstream pressure control following coalescing
Maximum Differential Pressure: 250 PSIG
Casing Pressure: As per manufacturer nameplate
Instrumentation;
Level / Condensate Monitoring: Rosemount Transmitter
Tag: BB76-LIT-700034B
- Instrumentation associated with condensate collection and drain system
- High-pressure rated instrument chamber
Configuration & Key Features;
- Parallel twin-vessel (A/B) arrangement
- Individual isolation valves per coalescer
- Common inlet and outlet headers
Designed for:
- High-availability CSG operations
- Online maintenance
- Reduced pressure drop
- Protection of downstream compression, metering, and pipelines
Asset Classification;
Twin Coal Seam Gas (CSG) Coalescer Vessel and Pressure Regulation Skid
AS 1210 Pressure Equipment – Hazard Level B
Skid Assembly;
Overall Dimensions (Approx.): 8.4 m (L) × 2.5 m (W) × 3.8 m (H)
- Structural steel skid, gal with grated deck
- Integrated access ladder and elevated maintenance platform
- Painted carbon steel pipework
- Outdoor-rated for field installation
Twin Gas Coalescer & Pressure Regulation Skid
Location: Queensland, Australia